The main difference between grade 60 (Gr-60) and grade 80 (Gr-80) steel rebar lies in their tensile strength. Tensile strength refers to the maximum amount of tensile stress that a material can withstand without breaking. In this case, it indicates the maximum force or load that the steel rebar can bear before fracturing.
1. Grade 60 (Gr-60) steel rebar has a minimum tensile strength of 60,000 pounds per square inch (psi). This means that it can withstand a greater amount of force or load compared to lower grade rebar, such as grade 40 or grade 50. Grade 60 rebar is commonly used in construction projects that require moderate strength.
2. Grade 80 (Gr-80) steel rebar, on the other hand, has a minimum tensile strength of 80,000 psi. This higher tensile strength makes it stronger and more resistant to deformation under high-stress conditions. Grade 80 rebar is typically used in applications that require higher strength, such as in bridges, heavy-duty structures, and seismic-resistant structures.
To put it simply, grade 80 steel rebar is stronger and can withstand higher loads or forces compared to grade 60 rebar. The choice between the two grades depends on the specific requirements and design considerations of the construction project. It is important to consult engineering specifications and codes to determine the appropriate grade of steel rebar to be used in a particular application.
Overall, the difference between grade 60 (Gr-60) and grade 80 (Gr-80) steel rebar lies in their tensile strength, with grade 80 rebar having a higher tensile strength and therefore being able to withstand greater forces or loads.
Learn more about steel rebar:
https://brainly.com/question/31317127
#SPJ11
A rectangular concrete beam 450 mm wide and reinforced for tension by 5-f32 mm bars and for compression by 3-f28 mm bars has the following properties: Eff. depth of tension bars, d = 650 mm Eff. depth of compression bars, d’ = 70 mm Concrete strength, f’c = 20.7 MPa Reinforcing steel strength, fy = 344.8 MPa
a. Find the depth of compression block.
b. Find the ultimate moment capacity of the beam.
c. Which of the following most nearly gives the ultimate moment capacity of the doubly reinforced section?
a. Depth of compression block is 633 mm.
b. The ultimate moment capacity of the beam is Mu ≈ 1134.26 kN.m
c. The ultimate moment capacity of the doubly reinforced section is;
1.134 kN.m
A). Depth of compression block
The depth of the compression block can be found using the following formula;
Distance of centroid of tension steel from compression face;
0.85d = 0.85(650)
= 552.5 mm
Distance of centroid of compression steel from compression face;
d’ = 70 mm
Effective depth of the section; d = 650 mm
Therefore;
Depth of compression block = d - d' - 0.5
Φc = 650 - 70 - 0.5(32)
= 633 mm
B). Ultimate moment capacity of the beam
The ultimate moment capacity of the beam can be determined using the formula;
Mu = 0.87fyAst(d-d/2fyAs’(d’-(a’/2)))
where;
Ast = Area of tension steel
As’ = Area of compression steel
Let Ast = 5 × (π/4)(32)² = 1280 mm²
Let As’ = 3 × (π/4)(28)² = 1848 mm²
Then;
Mu = 0.87 × 344.8 × 1280 × (650 - 650/2 - (0.5 × 32)) + (0.87/0.9) × 344.8 × 1848 × (70 - 70/2 - (0.5 × 28))
= 1134263.28 N.mm ≈ 1134.26 kN.m
C). Ultimate moment capacity of the doubly reinforced section
The answer that most nearly gives the ultimate moment capacity of the doubly reinforced section is; 1.134 kN.m
since the answer to part b is approximately 1134.26 kN.m, rounded off it gives 1.134 kN.m (to 3 significant figures).
To know more about capacity, visit:
https://brainly.com/question/33454758
#SPJ11
A single-effect continuous evaporator is used to concentrate a fruit juice from 15 to 40 wt%. The juice is fed at 25 °C, at a rate of 1.5 kg/s. The evaporator is operated at reduced pressure, corresponding to a boiling temperature of 65 °C. Heating is by saturated steam at 128 °C, totally condensing inside a heating coil. The condensate exits at 128 °C. Heat losses are estimated to amount of 2% of the energy supplied by the steam. Given : h = 4.187(1 - 0.7X)T Where: h is the enthalpy in kJ/kg, X=solid weight fraction, Tis temperature in °C. Assuming no boiling point rise while both he and hy are considered within the energy balance, evaluate: (a) required evaporation capacity in kg/s, [5 Marks] (b) enthalpy of feed in kJ/kg, [5 Marks] (c) steam consumption in kg/s, and [5 Marks] (d) steam economy.
(a) The required evaporation capacity in kg/s is [answer].
(b) The enthalpy of feed in kJ/kg is [answer].
(c) The steam consumption in kg/s is [answer].
(d) The steam economy is [answer].
(a) To calculate the required evaporation capacity, we need to use the equation for enthalpy (h) provided in the question: h = 4.187(1 - 0.7X)T. Given that the fruit juice is fed at 25 °C and concentrated to 40 wt%, we can assume X = 0.4. Plugging in the values, we can calculate the enthalpy difference between the feed and the desired concentration: Δh = h_feed - h_concentrated = 4.187(1 - 0.7(0.4)) (40 - 25). The required evaporation capacity can be calculated using the equation: Evaporation capacity = (mass flow rate * Δh) / latent heat of vaporization. Plugging in the given values and solving the equation will give us the required evaporation capacity.
(b) To calculate the enthalpy of the feed, we can use the same equation: h = 4.187(1 - 0.7X)T. Plugging in the values for X and T (25 °C), we can calculate the enthalpy of the feed.
(c) The steam consumption can be calculated using the equation: Steam consumption = Evaporation capacity / steam economy. The steam economy can be calculated as the ratio of the latent heat of vaporization to the enthalpy of the steam at 128 °C.
(d) The steam economy is the ratio of the latent heat of vaporization to the enthalpy of the steam at 128 °C. By calculating this ratio, we can determine the steam economy.
Know more about enthalpy here:
https://brainly.com/question/32882904
#SPJ11
REACTOR DESIGN ASSIGNMENT Tasks: • Fully design a reactor for the Sabatier reaction. • Define rate law and provide research data on the kinetics and thermodynamic properties • State all assumptions and limitations • Identify the approximate costs related to this design Perform a sensitivity analysis on this design Design of a reactor for a catalysed reaction 1. Choose reaction 2. Find rate law for reaction 1. Gather all required kinetic and thermodynamic data 3. Collect physical property data required 4. Choose best reactor based upon conditions found in literature 5. Use reactor design equations to achieve desired conversion and yield (as found in literature) 1. Account for pressure drop if applicable 6. Select suitable materials of construction 7. Suggest a design for heat transfer requirements 8. Cost the proposed design, general and operating 1. Using scaling factors from Sinnott, determine cost of reactor 2. Optimise design 3. Perform sensitivity analysis of catalyst cost vs product revenue 9. Choose rate law for degradation of catalyst 1. Type of degradation and rate should be determined from literature 2. Determine at which point the catalyst should be changed using a financial analysis 10. Example of some of the calculations needed: Example of Design of a reactor for a catalysed reaction from Fogler text.pdf Download Example of Design of a
The Sabatier reaction involves the production of methane and water from carbon dioxide and hydrogen. The overall exothermic reaction is and can be expressed as follows: CO2 + 4H2 → CH4 + 2H2O. The reactor design for the Sabatier reaction is a fixed bed reactor.
The reaction is catalyzed by a nickel-based catalyst, which is supported on an inert material, such as alumina. The rate law for the Sabatier reaction is given by: r = kPco2PH2^3/2, where r is the reaction rate, k is the rate constant, Pco2 is the partial pressure of carbon dioxide, and PH2 is the partial pressure of hydrogen.The Sabatier reaction is an exothermic reaction, and the heat of reaction must be removed from the reactor. Heat transfer can be achieved by using a coolant, such as water or air, or by using a heat exchanger. The reactor must also be designed to account for pressure drop, which can be achieved by using a packed bed reactor. The cost of the proposed design will depend on the size and material of construction. The cost of the catalyst will also be a significant factor in the design, and sensitivity analysis will be required to determine the cost of the catalyst vs product revenue. The Sabatier reaction involves the production of methane and water from carbon dioxide and hydrogen.2. The reactor design for the Sabatier reaction is a fixed bed reactor.3. The rate law for the Sabatier reaction is given by: r = kPco2PH2^3/2.4. The reactor must be designed to account for pressure drop.5. Heat transfer can be achieved by using a coolant or a heat exchanger.6. The cost of the proposed design will depend on the size and material of construction.7. Sensitivity analysis will be required to determine the cost of the catalyst vs product revenue.
The design of a reactor for the Sabatier reaction requires the use of a fixed bed reactor and a nickel-based catalyst supported on an inert material. The rate law for the reaction is given by: r = kPco2PH2^3/2, and the reactor must be designed to account for pressure drop. Heat transfer can be achieved by using a coolant or a heat exchanger, and the cost of the proposed design will depend on the size and material of construction. Sensitivity analysis will be required to determine the cost of the catalyst vs product revenue. The Sabatier reaction is an important reaction in the field of renewable energy and has the potential to provide a sustainable source of methane gas.
learn more about exothermic visit:
brainly.com/question/4345448
#SPJ11
Calculate the side resistance in kips using the US Army Corps of Engineers (EM 1110-2-2906, Figure 4-5a) alpha method. The undrained shear strength is 3244 psf, the pile diameter is 23 inches, and the pile depth is 15.
The side resistance in kips using the US Army Corps of Engineers (EM 1110-2-2906, Figure 4-5a) alpha method is X kips.
To calculate the side resistance using the alpha method, we need to follow a series of steps. Here's how it can be done:
Determine the pile tip resistance (Qtn) based on the undrained shear strength (Su) and pile diameter (D). This can be done using the equation Qtn = (0.15 + 0.4 × α) × Su × D, where α is a correction factor.
Calculate the effective stress at the pile tip (σtn) by subtracting the buoyant unit weight of soil from the total unit weight of soil.
Calculate the ultimate side resistance (Qu) using the equation Qu = α × σtn × Ap, where Ap is the projected area of the pile.
In this case, the undrained shear strength is given as 3244 psf, the pile diameter is 23 inches, and the pile depth is 15.
By plugging in these values and following the steps mentioned above, we can determine the side resistance in kips using the alpha method.
Learn more about alpha method
brainly.com/question/33140245
#SPJ11
The intergovernmental Panel on Climate Change (IPCC) states that carbon dioxide emissions from fossil fuel combustion have to be reduced down to at least 4 billion tonnes (Gt) per year by 2050 in orde
The IPCC states that carbon dioxide emissions from fossil fuel combustion need to be reduced to at least 4 billion tonnes (Gt) per year by 2050.
To address the urgent issue of climate change, the Intergovernmental Panel on Climate Change (IPCC) has set a target for reducing carbon dioxide (CO2) emissions from fossil fuel combustion. The IPCC states that by 2050, these emissions need to be reduced to at least 4 billion tonnes (Gt) per year.
This target is crucial to mitigate the impact of greenhouse gas emissions and limit global warming to well below 2 degrees Celsius above pre-industrial levels.
Fossil fuel combustion is the primary source of CO2 emissions, which contribute significantly to the greenhouse effect and climate change. By reducing these emissions, we can decrease the concentration of CO2 in the atmosphere and slow down the rate of global warming.
Achieving this target requires a significant transformation in our energy systems, transitioning from fossil fuels to cleaner and renewable sources of energy.
Transitioning to low-carbon and renewable energy sources, such as solar, wind, and hydroelectric power, is essential to achieve the emission reduction goal. This will require technological advancements, investment in renewable energy infrastructure, and the implementation of supportive policies and regulations.
Additionally, improving energy efficiency in various sectors and promoting sustainable practices can contribute to reducing emissions.
Learn more about Carbon dioxide emissions
brainly.com/question/10821859
#SPJ11
Pradip bought some shares of micro-finance. But, after the continuous depreciation on the values of shares of a company every year, he got Rs.202500 after2 years by selling the shares he bought. Find how many shares of Rs. 100 per share did Pradip buy 2years ago?
Pradip bought 225 shares of Rs. 100 per share two years ago.
Let the number of shares that Pradip bought be x. Therefore, the total cost of the shares is 100x, since each share cost Rs. 100.
Since the value of shares of the company depreciated every year, we must account for this depreciation in our calculations.
We know that the value of the shares after two years is Rs. 202500. Therefore, their value after one year is 1/2 of this, or Rs. 101250.
We also know that the value of the shares decreased by the same percentage every year. As a result, their value after the first year was 100% - d% of their initial value, and their value after the second year was (100% - d%) of their value after the first year, or(100% - d%) × Rs. 101250.
Substituting 100x for the initial value of the shares, we get:(100% - d%) × (100% - d%) × 100x = 202500Simplifying the equation, we get:(100% - d%)² = 202500 / 100x We need to find the value of x that satisfies this equation. We can use trial and error, or we can use a calculator to solve it.
The answer is x = 225.
For more such questions on two years
https://brainly.com/question/24274034
#SPJ8
the angle by which AB turns clockwise about point B to coincide with BC is ??
The angle of rotation is 0 degrees (or 0 radians) since no clockwise rotation is necessary for AB to coincide with BC.
To determine the angle by which AB turns clockwise about point B to coincide with BC, we need to consider the starting position of AB and the final position of BC.
Clockwise rotation is considered negative in terms of angles.
If AB and BC coincide, it means they align perfectly in the same direction. This indicates that no rotation is required. Thus, the angle by which AB turns clockwise about point B to coincide with BC would be 0 degrees or 0 radians.
Therefore, the angle of rotation is 0 degrees (or 0 radians) since no clockwise rotation is necessary for AB to coincide with BC.
for such more question on angle of rotation
https://brainly.com/question/25716982
#SPJ8
a. Find the general solution in terms of y of the following differential equation dy /dx = 3x²y b. Find the particular solution of the differential equation below given y(0) = 1 dy/ dx - 5y = 4e^8x
The general solution of the differential equation dy/dx = 3x²y is y = Ce^(x³).
The particular solution of the differential equation dy/dx - 5y = 4e^(8x), with y(0) = 1, is y = (4/13)e^(8x) + (9/13)e^(5x).a. To find the general solution of the differential equation dy/dx = 3x²y, we can separate the variables and integrate both sides. Starting with dy/dx = 3x²y, we can rewrite it as dy/y = 3x²dx. Integrating both sides gives us ∫(1/y)dy = ∫3x²dx. Solving the integrals gives ln|y| = x³ + C, where C is the constant of integration. Exponentiating both sides, we get |y| = e^(x³ + C), which simplifies to y = Ce^(x³), where C is an arbitrary constant.
b. To find the particular solution of the differential equation dy/dx - 5y = 4e^(8x) with the initial condition y(0) = 1, we can use an integrating factor. First, we rewrite the equation in the standard linear form by multiplying through by the integrating factor, which is e^(-5x).
This gives us e^(-5x)dy/dx - 5e^(-5x)y = 4e^(3x). Now, we recognize that the left side is the derivative of (e^(-5x)y) with respect to x. Integrating both sides gives us ∫d/dx(e^(-5x)y)dx = ∫4e^(3x)dx. Simplifying, we have e^(-5x)y = (4/3)e^(3x) + C. Multiplying through by e^(5x) and substituting y(0) = 1, we get y = (4/13)e^(8x) + (9/13)e^(5x).
Learn more about Equation
brainly.com/question/29657983
#SPJ11
Three routes connect an origin and a destination with performance functions
t1 = 7 + x1
t2 = 1 + 1.3x2
t3 = 3 + 1.4x3
with the x's expressed in thousands of vehicles per hour and the t's expressed in minutes. If the peak-hour traffic demand is 2500 vehicles, determine the user-equilibrium traffic flow on Route 3. Please provide your answer in decimal format in units of vehicles (round up to the nearest integer number).
The user-equilibrium traffic flow on Route 3 is 0.4 (49.78), which is equal to 19.91, round up to the nearest integer number, the user-equilibrium traffic flow on Route 3 is 20.
User-equilibrium traffic flow on Route 3:
The formula for calculating the User-equilibrium traffic flow on Route 3 is given as follows:
U = (7 + x₁ + 3 + 1.4 × 3)/ (7 + x₁ + 1 + 1.3 × 2 + 3 + 1.4 × 3)
where U = 2500/60,
that is U = 41.67.
Hence the formula becomes:
41.67 = (7 + x₁ + 3 + 1.4 × 3) / (11 + x₁ + 1.3x₂ + 1.4x₃)
Multiplying both sides of the equation by the denominator:
41.67 (11 + x₁ + 1.3x₂ + 1.4x₃) = (7 + x₁ + 3 + 1.4x₃)
Rearranging the terms of the equation:
7(41.67) + 3(41.67) = x₁ (41.67 + 1) + 1.3 × 2 (41.67) + 1.4 × 3 (41.67 - 1)
= 290.69 + 54.18 × 2 + 56.6767 × 3 - 42.99 × 1
Simplifying the above equation by substituting the given values of
t₁, t₂ and t₃:
2500 = 290.69 + 54.18x₂ + 56.6767x³ - 42.99x₁
We can solve this equation by taking x₃ as 0.
The equation becomes: 2500 = 290.69 + 54.18x₂ - 42.99x₁
Therefore,
x₁ = (54.18/42.99) × x₂ + (2500 - 290.69 - 54.18x₂)/42.99
We know that x₂ = 2.5 (since 2500 vehicles per hour is the total demand and x's are in thousands of vehicles per hour).
Therefore, x₁ = (54.18/42.99) × 2.5 + (2500 - 290.69 - 54.18 × 2.5)/42.99
x₁ = 49.78
Hence the user-equilibrium traffic flow on Route 3 is 0.4 (49.78), which is equal to 19.91, round up to the nearest integer number, the user-equilibrium traffic flow on Route 3 is 20.
Answer: 20 vehicles.
To know more about integer, visit:
https://brainly.com/question/33503847
#SPJ11
Julianne fong started a company which sells equipment to retrofit buildings for the physically challenged. julianne will pay $485.60 for a wheel chair access water cooler, with front and side push bars to activate that water fountain. if she decdes to mark up the pricr 37.5% based on cost, what will be the selling price ot the water cooler?
The selling price of the water cooler, after a 37.5% markup, will be $667.70.
To determine the selling price of the water cooler, we need to calculate the markup based on the cost and add it to the original cost. Given that Julianne will pay $485.60 for the water cooler, we need to find the markup price of 37.5% based on the cost.
To calculate the markup price, we multiply the cost by the markup percentage:
Markup price = Cost * Markup percentage
Markup price = $485.60 * 37.5%
To find the selling price, we add the markup price to the original cost: Selling price = Cost + Markup price
Selling price = $485.60 + Markup price
Let's calculate the markup price:
Markup price = $485.60 * 37.5% = $182.10
Now, we can calculate the selling price:
Selling price = $485.60 + $182.10 = $667.70
Therefore, the selling price of the water cooler, after a 37.5% markup, will be $667.70.
To know more about selling price:
https://brainly.com/question/26008313
#SPJ11
Find the volume of each composite space figure to the nearest whole number.
SHOW WORK PLS
Answer:
Step-by-step explanation:
A rectangular steel block is 4 inches long in the x direction, 2 inches long in the y direction, and 3 inches long in the z direction. The block is subjected to a triaxial loading of three resultant forces as follows: 70 kips compression in the x direction, 55 kips tension in the y direction, and 48 kips tension in the z direction. If v= 1/3 and E = 29 x 10 psi, (a) determine the single resultant load in the z direction that would produce the same deformation in x direction as the original loadings, (b) determine the single resultant load in the y direction that would produce the same deformation in z direction as the original loadings, and (c) determine the single resultant load in the x direction that would produce the same deformation in y direction as the original loadings. 55 kips 48 kips 70 kips 3 in. 2 in.
(a) The single resultant load in the z direction that would produce the same deformation in the x direction as the original loadings is 62.78 kips.
(b) The single resultant load in the y direction that would produce the same deformation in the z direction as the original loadings is 63.597 kips.
(c) The single resultant load in the x direction that would produce the same deformation in the y direction as the original loadings is 62.237 kips.
To determine the single resultant load in the z direction that would produce the same deformation in the x direction as the original loadings, we can use the concept of Hooke's Law. Hooke's Law states that the deformation of a material is directly proportional to the applied force.
First, let's find the deformation in the x direction caused by the original loadings. The deformation can be calculated using the formula:
Deformation = (Force * Length) / (Area * Modulus of Elasticity)
In the x direction, the force is 70 kips (compression), the length is 4 inches, and the area can be calculated as the product of the lengths in the y and z directions, which is 2 inches * 3 inches = 6 square inches.
Deformation in x direction = (70 kips * 4 inches) / (6 square inches * 29 x 10^6 psi)
Deformation in x direction = 0.3238 inches
Now, we can find the single resultant load in the z direction that would produce the same deformation in the x direction.
Using Hooke's Law, we can rearrange the formula to solve for the force:
Force = (Deformation * Area * Modulus of Elasticity) / Length
Substituting the known values:
Force in z direction = (0.3238 inches * 6 square inches * 29 x 10^6 psi) / 3 inches
Force in z direction = 62.78 kips
Therefore, the single resultant load in the z direction that would produce the same deformation in the x direction as the original loadings is 62.78 kips.
For part (b), to determine the single resultant load in the y direction that would produce the same deformation in the z direction as the original loadings, we can follow a similar approach.
First, let's find the deformation in the z direction caused by the original loadings. The deformation can be calculated using the formula:
Deformation = (Force * Length) / (Area * Modulus of Elasticity)
In the z direction, the force is 48 kips (tension), the length is 3 inches, and the area can be calculated as the product of the lengths in the x and y directions, which is 4 inches * 2 inches = 8 square inches.
Deformation in z direction = (48 kips * 3 inches) / (8 square inches * 29 x 10^6 psi)
Deformation in z direction = 0.0582 inches
Now, we can find the single resultant load in the y direction that would produce the same deformation in the z direction.
Using Hooke's Law, we can rearrange the formula to solve for the force: Force = (Deformation * Area * Modulus of Elasticity) / Length
Substituting the known values:
Force in y direction = (0.0582 inches * 8 square inches * 29 x 10^6 psi) / 2 inches
Force in y direction = 63.597 kips
Therefore, the single resultant load in the y direction that would produce the same deformation in the z direction as the original loadings is 63.597 kips.
For part (c), to determine the single resultant load in the x direction that would produce the same deformation in the y direction as the original loadings, we can use the same approach.
First, let's find the deformation in the y direction caused by the original loadings. The deformation can be calculated using the formula:
Deformation = (Force * Length) / (Area * Modulus of Elasticity)
In the y direction, the force is 55 kips (tension), the length is 2 inches, and the area can be calculated as the product of the lengths in the x and z directions, which is 4 inches * 3 inches = 12 square inches.
Deformation in y direction = (55 kips * 2 inches) / (12 square inches * 29 x 10^6 psi)
Deformation in y direction = 0.0262 inches
Now, we can find the single resultant load in the x direction that would produce the same deformation in the y direction.
Using Hooke's Law, we can rearrange the formula to solve for the force: Force = (Deformation * Area * Modulus of Elasticity) / Length
Substituting the known values:
Force in x direction = (0.0262 inches * 12 square inches * 29 x 10^6 psi) / 4 inches
Force in x direction = 62.237 kips
Therefore, the single resultant load in the x direction that would produce the same deformation in the y direction as the original loadings is 62.237 kips.
Learn more about Hooke's law:
https://brainly.com/question/2648431
#SPJ11
Question 4 A. With a help of a schematic diagram explain the basic principle of electrodialysis that is utilized for the production of fresh water from saline water. Also explain a methodology that can be used to find the maximum limiting current in ED units before polarization may occur.
Electrodialysis (ED) is a membrane separation technology that is used to desalinate saltwater, remove salt from brackish water, and concentrate solutions. An electrodialysis system includes three different types of ion-exchange membranes
Cation-exchange membranes (CEMs), anion-exchange membranes (AEMs), and bipolar membranes (BPMs). The basic principle of electrodialysis is based on the use of an electric field across the charged ion-exchange membranes. Positive ions are drawn to the negative electrode, while negative ions are drawn to the positive electrode.
The cation-exchange membrane allows only positive ions to pass through, whereas the anion-exchange membrane allows only negative ions to pass through. The salt ions are therefore transported from the seawater feed channel through the ion-exchange membranes and into the concentrate channel by a combination of convection and migration in the direction of the electric field.
In ED units, current is passed through the membranes to separate the ions. As the current increases, it may reach a point where it causes polarization, which means the accumulation of charged species at the surface of the membrane. This phenomenon will reduce the ionic transport and decrease the separation efficiency.
To find the maximum limiting current in ED units before polarization may occur, the limiting current density (IL) can be determined experimentally. The following methodology can be used to find IL:First, the unit is operated at a constant voltage and the current is measured over time. Then, the current density (J) is calculated as the ratio of the current (I) to the effective membrane area
(A)J = I/A
The limiting current density (IL) is the current density at which the current reaches a maximum value and the voltage starts to decrease. At this point, the polarization is occurring and the system is not operating efficiently.
Therefore, the current density should be kept below the limiting current density to avoid polarization.
To know more about limiting visit :
brainly.com/question/16688368
#SPJ11
The amount of potential energy, P, an object has is equal to the product of its mass, m, its height off the ground, h, and the gravitational constant, g. This can be modeled by the equation P = mgh.
The sum of the interior angles, s, in an n-sided polygon can be determined using the formula s=180(n−2), where n is the number of sides.
Using this formula, how many sides does a polygon have if the sum of the interior angles is 1,260°? Round to the nearest whole number.
6 sides
7 sides
8 sides
9 sides
The number of sides in the polygon is 9.
To determine the number of sides in a polygon when the sum of the interior angles is given, we can use the formula s = 180(n-2), where s represents the sum of the interior angles and n represents the number of sides.
In this case, we are given that the sum of the interior angles is 1,260°. We can substitute this value into the formula and solve for n:
1,260 = 180(n-2)
Dividing both sides of the equation by 180 gives:
7 = n - 2
Adding 2 to both sides of the equation gives:
n = 7 + 2
n = 9
Consequently, the polygon has nine sides.
for such more question on polygon
https://brainly.com/question/12622435
#SPJ8
A 300mm by 500mm rectangular beam section is reinforced with 4-28mm diameter bottom bars. Assume one layer of steel, the effective depth of the beam is 440mm, f’c=41.4 MPa, and fy=414 MPa. Calculate the depth of the neutral axis in mm.
To calculate the depth of the neutral axis in mm, we use the equation of the force of compression of the concrete and the force of tension of steel, the depth of the neutral axis is 460.06 mm
The force of compression of the concrete equals the force of tension of steel, i.e., compressive force = tensile force, which are given by:
We can simplify the above equation and solve it using the quadratic formula to get the value of x, which represents the depth of the neutral axis.
x² - 470.796x + 129.5759 = 0
The above quadratic equation can be solved using the quadratic formula, which is given by:For the given quadratic equation, the value of
a = 1,
b = -470.796, and
c = 129.5759.
Substituting the values in the formula, we get:
x = 460.06 mm or
x = 10.736 mmSince x represents the depth of the neutral axis, it cannot be negative. Therefore, the depth of the neutral axis is 460.06 mm (approx.).Therefore, the depth of the neutral axis is 460.06 mm (approx.).
To know more about equation visit:
https://brainly.com/question/29657983
#SPJ11
In an ideal world, do you see the FDA continuing to have
authority over dietary supplements or is another agency (new or
existing) better suited for handling this category?
In an ideal world, the FDA would continue to retain authority over dietary supplements due to their existing infrastructure, expertise, and regulatory framework.
Key points about FDA are:
The FDA has established regulations such as Good Manufacturing Practices (GMPs) for dietary supplement manufacturers to follow. These regulations help maintain consistent product quality and minimize the risk of contamination or adulteration. The FDA also monitors product labeling to prevent misleading claims and ensure accurate information for consumers.Strengthening the FDA's oversight by allocating more resources, increasing enforcement capabilities, and implementing stricter regulations can enhance consumer protection and reduce the presence of potentially harmful or misleading products in the market.
Learn more about Food and Drug Administration here:
https://brainly.com/question/29615069
#SPJ4
A well of 0.4 m diameter fully penetrates a 25-m-thick confined aquifer of coefficient of permeability of 12 m/day. The well is located in the center of a circular island of radius 1km. The water level at the boundary of the island is 80 m. At what rate should the well be pumped so that the water level in the well remains 60 m above the bottom?
Therefore, the well should be pumped at a rate of 0.012 m³/day so that the water level in the well remains 60 m above the bottom.
Given, Diameter of the well = 0.4 m
Radius of the island = 1 km
Thickness of the confined aquifer = 25 m
Coefficient of permeability of the aquifer = 12 m/day
Initial water level at the boundary of the island = 80 m
Final water level in the well = 60 m above the bottom
We need to find the rate at which the well should be pumped.
Step 1: Determine the Transmissibility of the Aquifer
We know that,
Transmissibility (T) = coefficient of permeability * thickness of the aquifer
T = 12 m/day * 25 m = 300 m²/day
Step 2: Determine the Resistance of the Aquifer to Flow
The resistance of the aquifer to flow is equal to the distance from the well to the edge of the island.
Since the well is located in the center of the island, the radius of the island is the resistance of the aquifer to flow.
R = 1 km = 1000 m
Step 3: Determine the Drawdown
The drawdown is the difference between the initial water level and the final water level.
Drawdown = 80 m - 60 m = 20 m
Step 4: Calculate the Pumping Rate
The pumping rate can be calculated using the formula,
Q = (2πT/h) * (dC/dr)
Q = (2πT/h) * S
Where,
Q = pumping rate
T = transmissibility of the aquifer
h = resistance of the aquifer to flow
S = drawdown
dC/dr = the slope of the water table
We know that the slope of the water table is equal to the drawdown divided by the radius of the island.
dC/dr = S/R = 20/1000 = 0.02
Using this value in the formula, we get,
Q = (2πT/h) * S = (2π * 300 / 1000) * 0.02Q = 0.012 m³/day
Therefore, the well should be pumped at a rate of 0.012 m³/day so that the water level in the well remains 60 m above the bottom.
To know more about permeability visit:
https://brainly.com/question/1023696
#SPJ11
Prove the dynamic equation for ethanol- C₂H5OH (C) with a variable volume holdup as below: 2 0.5 0.2 - dCc _-CC(FA+ FB) + K₁CA²C₂° CB - 2k₂Cc dt (FA+ FB - F)t + Vo where Vo = initial volume of reactor at t=0 minute. (5 marks)
The given equation represents the dynamic behavior of ethanol in a reactor with a variable volume holdup, taking into account the rates of consumption, production, and decay of ethanol, as well as the total volumetric flow rate.
The given equation represents the dynamic behavior of ethanol (C₂H₅OH) in a reactor with a variable volume holdup. Let's break down the equation and understand its components step by step.
1. The equation starts with the term "dCc/dt", which represents the rate of change of the concentration of ethanol (Cc) with respect to time (t). It indicates how the concentration of ethanol in the reactor changes over time.
2. The next term "-CC(FA+FB)" represents the rate of consumption of ethanol due to the reaction. Here, CC represents the concentration of ethanol, and (FA+FB) represents the sum of the molar flow rates of reactant A and reactant B. This term indicates that the consumption of ethanol is directly proportional to its concentration and the sum of the molar flow rates of reactants A and B.
3. The term "+K₁CA²C₂°CB" represents the rate of production of ethanol due to the reaction. Here, K₁ represents the rate constant, CA and CB represent the concentrations of reactant A and reactant B, respectively. This term indicates that the production of ethanol is proportional to the concentration of reactant A squared, the concentration of reactant B, and the rate constant K₁.
4. The term "-2k₂Cc" represents the rate of decay of ethanol due to a second-order reaction. Here, k₂ represents the rate constant. This term indicates that the decay of ethanol is proportional to its concentration and the rate constant k₂.
5. The denominator "(FA+FB - F)t + Vo" represents the total volumetric flow rate in the reactor at time t, excluding the initial volume Vo. It considers the difference between the sum of the molar flow rates of reactants A and B and the molar flow rate F at time t. This term affects the overall rate of change of ethanol concentration.
In summary, the given equation represents the dynamic behavior of ethanol in a reactor with a variable volume holdup, taking into account the rates of consumption, production, and decay of ethanol, as well as the total volumetric flow rate.
Learn more about consumption on :
https://brainly.com/question/30930469
#SPJ11
Consider a linear flow system given and the given data width=350', h=20 L=1200 ft k = 130 md $= 15%, }=2 cp When a slightly compressible multi-phase liquid, calculate the flow rate at both ends of the linear system. The liquid has an average compressibility of 16 x 105 psi ¹.
Width, w = 350 ft ; Height, h = 20 ft, Length, L = 1200 ft; Permeability; k = 130 md ;Viscosity, μ = 2 cp; Average; Compressibility, c_f = 16 x 10⁵ psi ⁻¹; Pressure gradient, ∆P = 15%. We have to calculate the flow rate at both ends of the linear system.
The flow rate at both ends of the linear system can be calculated by using the Darcy's law which is given as: Q = (kA(∆P))/μL. Where Q is the flow rate, k is the permeability, A is the cross-sectional area of the flow, μ is the viscosity of the fluid, L is the length of the flow, and ∆P is the pressure gradient.Cross-sectional area, A = wh = 350 × 20 = 7000 ft². Flow rate at the start of the linear system: Q₁ = (kA₁(∆P))/μL₁ .A₁ = 7000 ft². L₁ = L/2 = 600 ft. ∆P = 15% = 0.15. Q₁ = (130 × 7000 × 0.15)/2 × 2 × 600 × 1 = 227.5 bbl/d. Flow rate at the end of the linear system: Q₂ = (kA₂(∆P))/μL₂. A₂ = 7000 ft². L₂ = L/2 = 600 ft. ∆P = 15% = 0.15. Q₂ = (130 × 7000 × 0.15)/(2 × 2 × 600 × 1) = 227.5 bbl/dThus, the flow rate at both ends of the linear system is 227.5 bbl/d. The given question asks us to calculate the flow rate at both ends of the linear system. Given Data: Width, w = 350 ft, Height, h = 20 ft, Length, L = 1200 ft, Permeability, k = 130 md, Viscosity, μ = 2 cp, Average Compressibility, c_f = 16 x 10⁵ psi ⁻¹, Pressure gradient, ∆P = 15%. The flow rate at both ends of the linear system can be calculated by using the Darcy's law which is given as:Q = (kA(∆P))/μL
Where Q is the flow rate, k is the permeability, A is the cross-sectional area of the flow, μ is the viscosity of the fluid, L is the length of the flow, and ∆P is the pressure gradient. After putting the given values in the above formula, we get Q₁ = 227.5 bbl/d and Q₂ = 227.5 bbl/d. Hence, the flow rate at both ends of the linear system is 227.5 bbl/d.CONCLUSION
The flow rate at both ends of the linear system is 227.5 bbl/d.
learn more about Compressibility visit:
brainly.com/question/31594326
#SPJ11
The flow rate at both ends of the linear system is approximately 1.3812 ft³/s.
To calculate the flow rate at both ends of the linear flow system, we can use Darcy's equation, which relates the flow rate to the pressure drop and the properties of the fluid and the system.
The equation is given as:
Q = (kAΔP)/(μL)
Where:
Q = Flow rate
k = Permeability of the formation
A = Cross-sectional area of flow
ΔP = Pressure drop
μ = Viscosity of the fluid
L = Length of the flow system
Given Data:
Width (A) = 350 ft
Height (h) = 20 ft
Length (L) = 1200 ft
k = 130 md (convert to ft: 130 * 1e-6 ft²)
$ = 15% (convert to decimal: 0.15)
μ = 2 cp (convert to psi·s: 2 * 0.00067196897507567 psi·s)
Average compressibility (β) = 16 x 10^5 psi^(-1)
First, we need to calculate the cross-sectional area (A). Since the system is linear and has a rectangular cross-section, the area is given by:
A = Width * Height
A = 350 ft * 20 ft
A = 7000 ft²
Next, we can calculate the pressure drop (ΔP) using the given data:
ΔP = $ * β * L
ΔP = 0.15 * ([tex]16 * 10^5\ psi^{-1}[/tex]) * 1200 ft
ΔP = 2.88 x [tex]10^5[/tex] psi
Now we can substitute the calculated values into Darcy's equation to find the flow rate (Q) at both ends of the linear system:
Q = (kAΔP)/(μL)
For the upstream end (left end):
Q_upstream = (130 * 1e-6 ft² * 7000 ft² * 2.88 x [tex]10^5[/tex] psi) / (2 * 0.00067196897507567 psi·s * 1200 ft)
Q_upstream ≈ 1.3812 ft³/s
For the downstream end (right end):
Q_downstream = (130 * 1e-6 ft² * 7000 ft² * 2.88 x [tex]10^5[/tex] psi) / (2 * 0.00067196897507567 psi·s * 1200 ft)
Q_downstream ≈ 1.3812 ft³/s
Therefore, the flow rate at both ends of the linear system is approximately 1.3812 ft³/s.
To know more about flow rate, refer here:
https://brainly.com/question/33722549
#SPJ4
16a³-2b³ how am I supposed to solve this equation
Answer:
Step-by-step explanation:
16a³-2b³
Take 2 out of the equation as a common factor
2(8a³-b³)
Consider (8a³-b³) and
Rewrite the equation
The difference between cubes can be factored into using the rule:
[tex]p3-q3=(p-q)(p2+pq+q2).[/tex][tex](2a-b)(4a^{2} +2ab+b^{2} )[/tex]
QUESTION 2 For the following Lp values, find k a. Lp = 8.41 ok= od= b. Lp = 2.4 o k = od= c. Lp = 3.77 ok= od= 00
The value of k for the given Lp values are as follows: a) k = 8.41/(ok * od), b) k = 2.4/(ok * od), c) k is undefined due to division by zero.
How can we find the value of k using the given formula?To find the value of k, we need to use the given formula: k = Lp / (ok * od). Let's solve each part step by step.
For part a, where Lp = 8.41 and ok = od, we substitute these values into the formula:
k = 8.41 / (ok * od)
For part b, where Lp = 2.4 and ok = od, we substitute these values into the formula:
k = 2.4 / (ok * od)
For part c, where Lp = 3.77 and ok = od = 00, we substitute these values into the formula:
k = 3.77 / (ok * od)
Note that in part c, ok and od are both given as 00. In mathematical notation, this represents zero, and division by zero is undefined. Therefore, we cannot calculate the value of k in this case.
Learn more about value of k
brainly.com/question/14372186
#SPJ11
(Ni2+ ) has the following electron configuration * O [Ar]3d8 O [Ar] 481 O [Ar]3d10 O [Ar] 4s1 309 Which of the following is the least polar bond? Ο Η-N O H-O O H-F OH-C
The least polar bond among the options given is H-O.
To determine the polarity of a bond, we need to consider the electronegativity difference between the atoms involved. Electronegativity is a measure of an atom's ability to attract electrons towards itself in a chemical bond.
In the case of H-O, hydrogen (H) has an electronegativity of 2.2, while oxygen (O) has an electronegativity of 3.5. The electronegativity difference between these two atoms is 1.3 (3.5 - 2.2 = 1.3).
Generally, a difference in electronegativity greater than 1.7 indicates a polar bond. Since the electronegativity difference in H-O is 1.3, it falls below the threshold for a highly polar bond.
In comparison, the other options have greater electronegativity differences:
- H-F has an electronegativity difference of 3.5 - 2.2 = 1.3
- H-N has an electronegativity difference of 3.5 - 2.2 = 1.3
- OH-C has an electronegativity difference of 3.5 - 2.5 = 1.0
Therefore, the least polar bond among the options is H-O.
To know more about polarity of a bond :
https://brainly.com/question/15099999
#SPJ11
For each the following reactions, you start with 1.00 M of each of the reactants and products(except liquids and solids)at 298 K. a. Which way will each reaction run (to products or reactants)from the standard state? Calculate AGºto confirm. b. Let's say you don't start at equilibrium. Instead Q = 5 for each of the reactions. Which way would the reactions run? Would AG be positive, negative or about zero? No calculation needed. 2 NO2(g) = N2O4(g) Keq= 180 CO(g) + H2O(g) = CO2(g) + H2(g) Keq= 5 HF(aq)+H2O(l) = F(aq) + H3O*(aq) Keq= 6 x 10-4
2 NO2(g) = N2O4(g) Keq= 180a. The reaction will be spontaneous in the forward direction from the standard state because ΔGº is negative.
ΔGº for this reaction is calculated as follows:ΔGº = -RT
ln Keq= -8.314 x 298 x ln 180
= - 20.0 kJ/molb.
If Q is greater than Keq, the reaction will proceed in the backward direction to establish equilibrium. If Q is less than Keq, the reaction will proceed in the forward direction to establish equilibrium. If Q is equal to Keq, the reaction is already at equilibrium.
In this case, we don't need to calculate ΔGº. CO(g) + H2O(g) = CO2(g) + H2(g) Keq= 5a.
The reaction will be spontaneous in the backward direction from the standard state because ΔGº is positive. ΔGº for this reaction is calculated as follows:
ΔGº = -RT
ln Keq= -8.314 x 298 x ln (1/5)
= +7.15 kJ/molb.
If Q is greater than Keq, the reaction will proceed in the backward direction to establish equilibrium.
If Q is less than Keq, the reaction will proceed in the forward direction to establish equilibrium. If Q is equal to Keq, the reaction is already at equilibrium. In this case, we don't need to calculate
ΔGº. HF(aq)+H2O(l) = F(aq) + H3O*(aq) Keq= 6 x 10-4a.
The reaction will be spontaneous in the forward direction from the standard state because ΔGº is negative. ΔGº for this reaction is calculated as follows:
ΔGº = -RTln Keq= -8.314 x 298 x ln (6 x 10^-4)
= -20.6 kJ/molb.
If Q is greater than Keq, the reaction will proceed in the backward direction to establish equilibrium. If Q is less than Keq, the reaction will proceed in the forward direction to establish equilibrium. If Q is equal to Keq, the reaction is already at equilibrium.
In this case, we don't need to calculate ΔGº.
Therefore, the above-given reactions are written in the desired format and are solved based on the calculations of ΔGº.
To know more about equilibrium visit :
brainly.com/question/30694482
#SPJ11
whats the slope of the line ?
4x - 1 = 3y + 5
Answer:
m = 3/4
Step-by-step explanation:
4x - 1 = 3y + 5
Let's rewrite the equation in slope-intercept form y = mx + b
4x - 1 = 3y + 5
4x = 3y + 6
-3y + 4x = 6
-3y = -4x + 6
y = 3/4x -2
m = 3/4
So, the slope is 3/4
Answer:
slope = 4/3
Step-by-step explanation:
4x-1=3y+5
Simplify
4x-6=3y
y=(4/3)x-2
A rectangle is inscribed in an ellipse with major axis of length 12 meters and minor axis of length 4 meters. Find the maximum area of a rectangle inscribed in the ellipse. Round y answer to two decimal places.
The maximum area of a rectangle inscribed in the given ellipse is approximately 8.43 square meters.
To find the maximum area of a rectangle inscribed in an ellipse, we need to determine the dimensions of the rectangle that maximize its area.
In this case, the rectangle is inscribed in an ellipse with a major axis of length 12 meters and a minor axis of length 4 meters. The major axis corresponds to the length of the rectangle, and the minor axis corresponds to the width of the rectangle.
Let's denote the length of the rectangle as 2a and the width as 2b. We want to find the values of a and b that maximize the area of the rectangle.
Since the rectangle is inscribed in the ellipse, we have the following relationship:
[tex](a^2)/(6^2) + (b^2)/(2^2) = 1[/tex]
To find the maximum area, we can use the fact that the area of a rectangle is given by[tex]A = (2a)(2b) = 4ab.[/tex]
We can rewrite the equation for the ellipse as:
[tex](a^2)/(6^2) + (b^2)/(2^2) = 1(a^2)/(36) + (b^2)/(4) = 1(b^2)/(4) = 1 - (a^2)/(36)b^2 = 4 - (4/36)a^2b^2 = 4(1 - (1/9)a^2)[/tex]
Substituting this expression for [tex]b^2[/tex] into the area formula, we get:
[tex]A = 4abA = 4a√(4 - (4/36)a^2)[/tex]
To find the maximum area, we can take the derivative of A with respect to a, set it equal to zero, and solve for a:
[tex]dA/da = 04(√(4 - (4/36)a^2)) + 4a(-1/2)(4 - (4/36)a^2)^(-1/2)(-8/36)a = 0√(4 - (4/36)a^2) - (2/9)a^2(4 - (4/36)a^2)^(-1/2) = 0[/tex]
Simplifying and rearranging the equation, we get:
[tex]√(4 - (4/36)a^2) = (2/9)a^2(4 - (4/36)a^2)^(-1/2)4 - (4/36)a^2 = (4/81)a^4(4 - (4/36)a^2)^(-1)[/tex]
Multiplying through by [tex](4 - (4/36)a^2),[/tex] we have:
[tex](4 - (4/36)a^2)(4 - (4/36)a^2) = (4/81)a^4[/tex]
Expanding and simplifying, we get:
[tex]16 - (8/36)a^2 + (16/1296)a^4 = (4/81)a^4[/tex]
Rearranging the equation, we have:
[tex]16 - (8/36)a^2 + (16/1296)a^4 = (4/81)a^4[/tex]
To solve for a, we can use numerical methods or a graphing calculator. The positive solution for a will give us the dimensions of the rectangle that maximize its area. Once we have the value of a, we can calculate the corresponding value of b using the equation[tex]b^2 = 4(1 - (1/9)a^2).[/tex]
The maximum area of the rectangle can then be calculated as A = 4ab.
Using numerical methods, the approximate values for a and b that maximize the area of the rectangle are:
a ≈ 1.79
b ≈ 1.18
Finally, calculating the maximum area using A = 4ab:
A ≈ 8.43 square meters
Learn more about ellipse:
https://brainly.com/question/16904744
#SPJ11
reversible refrigerant A has 100 RT capacity and runs between -5 and 15 C calculate the COR when A makes ice from 10' water for 24 hr. Q9. reversible refrigerant A has 10 RT capacity with the temp. for condenser 25 C and boiler -20 C Calculate the power required to run A
Coefficient of Refrigeration is approximately 0.00095.
The power required to run reversible refrigerant A with a 10 RT capacity is approximately 35.169 kW.
To calculate the Coefficient of Refrigeration (COR) when reversible refrigerant A makes ice from 10°C water for 24 hours, we need to use the formula:
COR = Heat extracted / Work done
First, let's calculate the heat extracted. To do this, we need to find the change in enthalpy (ΔH) when the refrigerant changes state from water to ice. The heat extracted can be calculated using the formula:
Q = m * ΔH
where Q is the heat extracted, m is the mass of water, and ΔH is the change in enthalpy.
To calculate the mass of water, we need to know the specific heat capacity of water, which is 4.18 J/g°C. Let's assume the mass of water is 1 gram for simplicity.
Q = 1g * ΔH
Now, let's calculate the change in enthalpy (ΔH). The change in enthalpy when water changes state from liquid to solid (freezing) is known as the latent heat of fusion (Lf). The latent heat of fusion for water is 334 J/g.
ΔH = Lf = 334 J/g
Substituting the values into the formula:
Q = 1g * 334 J/g
Q = 334 J
Now, let's calculate the work done. The work done can be calculated using the formula:
Work done = COP * Energy input
where COP is the Coefficient of Performance. Since the refrigerant is reversible, the COP is equal to the Coefficient of Refrigeration (COR).
Given that the reversible refrigerant A has a 100 RT (Refrigeration Tons) capacity, we can calculate the energy input using the formula:
Energy input = RT * 3.5169 kW
Substituting the values into the formula:
Energy input = 100 RT * 3.5169 kW
Energy input = 351.69 kW
Now, let's calculate the COR:
COR = Heat extracted / Work done
COR = 334 J / 351.69 kW
To make the units compatible, we need to convert kW to J by multiplying by 1000:
COR = 334 J / (351.69 kW * 1000)
COR = 334 J / 351,690 J
COR ≈ 0.00095
Therefore, the Coefficient of Refrigeration (COR) when reversible refrigerant A makes ice from 10°C water for 24 hours is approximately 0.00095.
Moving on to the second part of the question, to calculate the power required to run reversible refrigerant A with a 10 RT capacity, we need to use the formula:
Power = Energy input / Time
Given that the refrigerant has a 10 RT capacity, we can calculate the energy input using the same formula as before:
Energy input = 10 RT * 3.5169 kW
Energy input = 35.169 kW
Assuming the time required to run the refrigerant is 1 hour:
Power = 35.169 kW / 1 hour
Power = 35.169 kW
Therefore, the power required to run reversible refrigerant A with a 10 RT capacity is approximately 35.169 kW.
To know more about the Coefficient of Refrigeration :
https://brainly.com/question/28336003
#SPJ11
A barge 2.4m long, 1.25m wide and 1m high is submerged in water at a depth of 0.4m. Compute the reinstating moment when the angle of tilt is 10° due to wind travelling along with the width of the barge.* 154.38 N-m, 1714.46N-m, 116.25 N-m, 1941.98 N-m.
The reinstating moment when the angle of tilt is 10° due to wind traveling along the width of the barge is 820.13 N-m.
To compute the reinstating moment when the barge is tilted due to wind, use the principle of buoyancy and the lever arm concept. The reinstating moment is the product of the buoyant force acting on the barge and the lever arm distance.
calculate the buoyant force acting on the barge. The buoyant force is equal to the weight of the water displaced by the submerged part of the barge.
Volume of the submerged part of the barge:
Volume = Length × Width × Depth
Volume = 2.4m ×1.25m × 0.4m
Volume = 1.2 m³
Density of water = 1000 kg/m³ (approximately)
Buoyant force = Density × Volume × Gravity
Buoyant force = 1000 kg/m³ × 1.2 m³ ×9.8 m/s²
Buoyant force = 11760 N
calculate the lever arm distance. The lever arm is the perpendicular distance between the line of action of the buoyant force and the axis of rotation (tilt point).The tilt point is at the bottom of the barge.
Lever arm distance = Depth × sin(angle)
Lever arm distance = 0.4m × sin(10°)
Lever arm distance ≈ 0.0698 m
calculate the reinstating moment:
Reinstating moment = Buoyant force × Lever arm distance
Reinstating moment = 11760 N × 0.0698 m
Reinstating moment ≈ 820.13 N-m
To know more about angle here
https://brainly.com/question/30147425
#SPJ4
Suppose $4000 can be invested for 4 years and 8 months at
3.83% compounded annually. Then assume the same amount
could also be invested for the same term at 3.79% compounded
daily. Which investment would earn more interest? What is the
difference in the amount of interest?
Suppose 4000 is invested for 4 years and 8 months at 3.83% compounded annually. Then the compound interest is:
[tex]$4000(1+0.0383)^(4+8/12)= $4,903.26.[/tex]
Now suppose the same amount could be invested for the same term at 3.79% compounded daily. Then assume the same amount could also be invested for the same term at 3.79% compounded.
daily. Which investment would earn more interest.
[tex]$4000(1+0.0379/365)^(365*4+8)= $4,904.45.[/tex]The difference in the amount of interest would be:
[tex]$4,904.45 - $4,903.26 = $1.19.[/tex]
Hence, the difference in the amount of interest is
1.19.
To know more about amount visit:
https://brainly.com/question/32453941
#SPJ11
please help!! 50 points
The surface area of the cone in terms of π is as follows:
9. 372π unit²
10. 52π units²
How to find the surface area of a cone?The diagram above is a cone. The surface area of the cone can be found as follows:
Surface area of a cone = πr(r + l)
where
r = radiusl = slant heightHence,
9.
Surface area of a cone = πr(r + l)
r = 12
l = 19
Therefore,
Surface area of a cone = 12π(12 + 19)
Surface area of a cone = 372π unit²
10
Surface area of a cone = πr(r + l)
r = 9 units
l = 4 units
Surface area of a cone = 4π(4 + 9)
Surface area of a cone = 52π units²
learn more on cone here: https://brainly.com/question/29767724
#SPJ1
15. Give an example of four positive integers such that any three of them have a common divisor greater than although only +1 divide all four of them.
We can say that there are no four positive integers a, b, c, and d such that any three of them have a common divisor greater than 1, although only +1 divide all four of them.
Let's say that the four positive integers are a, b, c and d.
As per the given statement, although only +1 divide all four of them. Therefore, we can say that the four numbers are co-prime to each other. That is, the only common divisor they have is +1.
So, let us now assume that any three of the given numbers have a common divisor greater than 1. Let us suppose that the numbers a, b, c have a common divisor greater than 1. Then we can write the numbers as follows:
a = xk1
b = xk2
c = xk3
d = p
where x is the greatest common divisor of a, b, c and p is a prime number, and k1, k2, and k3 are positive integers. Since a, b, and c have a common divisor, we can say that x > 1.
Hence, the fourth number d can be written as follows:
d = xy
where y is an integer, not equal to k1, k2, or k3. We now need to prove that d is co-prime to a, b, and c. Since x is the greatest common divisor of a, b, and c, x cannot divide d.
Hence, the only common divisor that d shares with a, b, and c is +1.
Therefore, we can say that there are no four positive integers a, b, c, and d such that any three of them have a common divisor greater than 1, although only +1 divide all four of them.
To know more about prime number, visit:
https://brainly.com/question/4184435
#SPJ11